Hydrogen Purifier
High Flow 8000i Series
|
Power+Energy's Model 8000i Hydrogen Purifier Systems provides a cost effective solution for producing large volumes of ultra-pure hydrogen gas. Each purifier includes an integrated P120 controller that provides an easy-to-use interface for controlling the purifier unit. The P120 also displays valuable system status and operating conditions information.
With its automatic leak testing on shutdown and immunity to power outages, the 8000i series is an ideal choice for those requiring a dependable comprehensive system for their UPH production needs.
Each of the 25 models available in the 8000i series is configured to output a specific volume of UPH gas. The flow rates across the series range from between
15
to
325
standard liters per minute (SLPM). It is the number of PdAg purifier membranes in the unit that determines the model's total UPH output flow. For example, the PE-8245 model outputs 245 SLPM.
Each tool below allows you to determine the right PE 8000i model for your application. The first tool is P+E's proprietary
Purifier Simulation software
. This downloadable, interactive program graphically illustrates the flow of gas through the purifier as you adjust the simulated control system. The second tool is a simplified
online version
that recommends an appropriate PE 8000i model based on your feed pressure, UPH pressure, and flow requirements. |
|
|
PE 8000i System Simulator Software
GO
|
|
|
|
PE 8000i Online Sizing Calculator
GO
|
|
8000i Series Product Highlights:
• Reliable P+E “
Inside-Feed
” palladium cell design
• Immune to power failure
• Compact design for large UPH flows
• Simple one-button operation
• Proportional, differential, integrating temperature controller
• Self monitoring by P120 Controller unit
• Displays system status and all relevant system information
• Automatic leak check on shutdown
• Leak Test mode for user
• RS-232 for computer interface
• Accelerated Life Testing reliability
• Two (2) year warranty
Mechanical Specifications:
• Tubing / cell material: 316L stainless steel
• Membranes tested to 200 PSIG
• Helium leak test 1 x 10-9 cc/sec
• Tubing connections on the back panel are 1/4" face seal fittings
• Finish on all UPH tubing electro-polished
• Finish on all UPH cell surfaces micro-polished
Process Specifications:
• Ultra-pure hydrogen purity: 99.9999999% at UPH flow > 20% of max flow or > 15 SLPM
, whichever is less.
• Ultra-pure hydrogen flow rate 15-325 SLPM
• Hydrogen gas feed inlet pressure: 36 - 200 PSIG
• Feed hydrogen gas purity: ~99.95%
• Hydrogen bleed outlet: typical 1 to 4% of feed hydrogen
• Typical average power consumption: < 700 watts
|
|